Station Notes 

  • Adopted by the AEC
  • The site is a sited on NPS land in the Yukon-Charley Rivers National Preserve on the north side of Coal Creek mining camp at the old water tank location.

  • The site is a 5-10 minute walk from the air strip and up a steep hill. It's a tough walk if you are carrying a lot of weight. NPS staff have provided ATV rides from the airstrip to the base of the steep hill in the past. Large amounts of equipment are most easily moved to the site via helicopter sling load with a long line

Service Plan

Site Access

  • Fixed wing and walk or atv (coordinate with NPS) to site
  • Site Map

Site Contact

Site Visits

  •  2019_09_16 Removal (Adopted by AEC)
    STATION CODE: TA.I26K

     

    STATION LOCALE DESCRIPTION: Coal Creek Mining Camp, AK, USA

     

    STATION REMOVAL LOG DATE: 20190916

     

    STATION/SENSOR DOWN TIME (UTC): N/A
    REMOVAL DESCRIPTION: Site was adopted by AEC and has not been removed.
    ACTIONS TAKEN: VSAT modem and router replaced with AEC equipment. 
    LAT/LONG OF SENSOR HOLE: N/A

     

    Top of Casing to hole bottom (indicate if sand present or evacuated): N/A
     Bottom of wellcap to grade level: N/A
    SENSOR ORIENTATION MEASUREMENTS: 
    Measured with Octans Unit: N/A
    Measured with rods on pin: N/A
    Casing/wellcap marked with reference orientation: N/A
    SENSOR ORIENTATION: N/A
    COMMENTS: 
    The purpose of this visit was to inspect the site and register a new VSAT modem so that we can take over data acquisition from TA .
    The VSAT modem swap went smoothly.
    REMOVED: 
    VSAT modem
    DAMAGE: 
    N/A
    LEFT AT SITE: N/A
    VISITORS:
    Nate Murphy
    Evan McArthur
    Lea Gardine
    NEXT VISIT:  N/A
    SITE STATUS:  N/A
    HOLE STATUS: N/A
  •  2019_05_07 Service (R. Bierma, S. Dalton)

    USArray Station Service Report
    Form V1.0

    STATION CODE:
    TA.I26K

    STATION Locale Description:
     Coal Creek, AK, USA

    STATION SERVICE LOG DATE:
    20190507


    STATION/SENSOR DOWN TIME (UTC)
    ~2330-2359 UTC

    SERVICE DESCRIPTION:

    Upgrades to comms power controlling and distribution

    Add weather station

    Swap VIE and router


    UPON ARRIVAL:

    Station in very good condition. NPS told said that we were among the first people out at Coal Creek this year, so there were no guarantees the airstrip would be landable. It was perfectly dry and level. We also had some concern about bears in the area, but we only saw sign of moose, wolf, beaver, and bunny on the 1/4 mile walk to the station.


    ACTIONS TAKEN:

    Swap upper portion of the Hut Antenna Mount. The old mount didn't have secondary nipples to accommodate an external GPS antenna.

    Swap LinkSys router for a Mikrotik, same network info, 67.47.8.102/30. Change power distribution blocks inside comms box to include blocking diodes. Omron solid state timer set to 1 hour ON/4 hours OFF. Add necessary components onto Hut panel, including a Crydom solid state relay, to allow for DC VSAT power control via XI-202.

    Add Vaisala WXT536 and standard Weather Station Mount. Move GPS outside.

    VIE was swapped due to possible lack of QEP jumpers. Initially there was no response from the Vaisala on the EP page in Willard. After some troubleshooting, and due to a fortunate coincidence of working with Vaisalas recently in the lab, it was determined that the protocol/baud rate on the Vaisala was set to RS232 at 19200, instead of SDI12. Once the change was made via the service port on the Vaisala, the weather station information populated on the EP page almost immediately.


    EQUIPMENT REMOVED:

    baler sn = 15297
    baler bc = 5006258

    QEP sn 116792
    QEP bc = 5001069

    infra Setra sn = 4719252
    infra Setra bc = 5017791

    infra NCPA sn = H111100350
    infra NCPA bc = 5011608

    Power System 1
    Power Pnl ver. =Genasun VIE
    Power Pnl bc = 5009241
    Power Brd sn = 485
    Power Brd bc = 5010310
    Genasun charge controller bc = 5017791

    EQUIPMENT INSTALLED:

    baler sn = 18424
    baler bc = 5010821

    QEP sn = 117024
    QEP bc = 5001580
    Vaisala WXT536 met station: bc = 5019046, sn = P4620685

    infra Setra sn = 4694590
    infra Setra bc = 5011671

    infra NCPA sn = H110330156
    infra NCPA bc = 5011080

    Power System 1.6.5
    Power Pnl ver. = Genasun VIE
    Power Pnl bc = 5009327
    Power Brd sn = 40
    Power Brd bc = 5009641
    Genasun charge controller = 5017798

    COMMENTS:

    door was taped with aluminum tape prior to departure


    VISITOR: 
    Ryan Bierma
    Scott Dalton (AEC)

    ON NEXT VISIT:

    Option to move comms system Morningstar charge controller into the Grizzly cooler instead of inside the comms box within the hut.

    Option to add a standard XI-202 mount onto the side wall, i.e. flange with nipples and angle tacked to the Hut panel. The antenna is currently zip tied to the top shelf of the Hut panel.

    CHANGES AFFECT INSTRUMENT RESPONSE:

    n/a

  • 2017_06_23 Service (K. Aderhold, Amin, D. Bloomquist)
  • 2016_07_27 Service (R. Bierma)
  • 2016_06_08 Service (R. Bierma, K. Aderhold)
  • 2015_10_15 Service (D. Bloomquist)
  • 2015_09_12 Install (J. Miner, D. Bloomquist)
  • No Recon Report

Station Health

PDFs

ANF Station Page

MesoWest

65.30636, -143.15405, Elev: 1108ft


Permits

LandownerPermit ExpiresNotificationStipulations

NPS-Yukon-Charley Rivers (YUCH-2018-SCI-0001)


 Close-out Release Form

12/31/2020

Yes, ~1 week,

None
AEC-Primary Permit HolderNAYes, ~1 week AECAs of 8/15/2019 this station has been adopted by the AEC