K13K (AEC-AON)

K13K (AEC-AON)

Station Notes

  • ADOPTED BY AEC
  • None at this time

Service Plan

Site Access

  • Helicopter from St Mary's or Bethel

Site Contact

  • None at this time

Site Visits

  •  2020_09_22 Removal (Adopted by AEC)
    USArray Station Removal Report 
    Form V1.5

     

    STATION CODE: TA.K13K

     

    STATION LOCALE DESCRIPTION: Kusilvak Mountain, AK, USA

     

    STATION REMOVAL LOG DATE: 20200922

     

    STATION/SENSOR DOWN TIME (UTC): N/A
    REMOVAL DESCRIPTION: Site was adopted by AEC and has not been removed.
    ACTIONS TAKEN: Site was not visited during the adoption process. 
    LAT/LONG OF SENSOR HOLE: N/A

     

    Top of Casing to hole bottom (indicate if sand present or evacuated): N/A
     Bottom of wellcap to grade level: N/A
    SENSOR ORIENTATION MEASUREMENTS: 
    Measured with Octans Unit: N/A
    Measured with rods on pin: N/A
    Casing/wellcap marked with reference orientation: N/A
    SENSOR ORIENTATION: N/A
    COMMENTS: 
    BGAN site, remote acquisition changeover to AK network.
    REMOVED: N/A
    DAMAGE: N/A
    LEFT AT SITE: N/A
    VISITORS:
    Nate Murphy
    NEXT VISIT:  N/A
    SITE STATUS:  N/A
    HOLE STATUS: N/A
  •  2020_07_15 Service (R. Bierma, J. Miner)

    USArray Station Service Report
    Form V1.0

    STATION CODE:
    TA.K13K

    STATION Locale Description:
    Kusilvak Mountain, Alaska

    STATION SERVICE LOG DATE:
    20200715

    STATION/SENSOR DOWN TIME (UTC):

    Station offline for ~5 minutes, 12:45 for media swap


    SERVICE DESCRIPTION:

    Trouble shoot Vaisala weather station outage and baler media swap

    UPON ARRIVAL:  

    Station in good condition, no signs of bear damage.

    The met station was not running. 

    ACTIONS TAKEN: 

    Verified the station configuration.  Tested a new cable and a new Vaisala WXT-536.  Also tested the old cable that showed signs of corrosion.  The old cable was still functioning, but was swapped anyway due to the visual corrosion.

    Vaisala WXT536 swapped in for WXT520, cable changed. Environmental processor firmware was already upgraded to 1.10.

    Baler media swap.

    Soil temperature sensor batteries changed and data downloaded.


    EQUIPMENT REMOVED:

    Vaisala WXT520 barcode: 5018763

    Vaisala WXT520 s/n: N4010166


    EQUIPMENT INSTALLED:

    Vaisala WXT536 barcode: 5019064

    Vaisala WXT536 s/n: R2210115


    COMMENTS:
    Corrosion was noteworthy on external metal components and cables.  Courtesy of Bering Sea influence. 

    Door taped prior to departure.


    VISITOR: 

    1. Bierma
    2. Miner
    3. Bue (Alpine Air)


    ON NEXT VISIT:

    n/a

    CHANGES AFFECT INSTRUMENT RESPONSE:

    n/a

  • 2018_08_21 Service (R. Bierma, D. Bloomquist)
  • 2018_04_20 Service (J. Miner, D. Bloomquist)
  • 2017_05_31 Install (R. Bierma, M. Sanders, J. Theis)

Station Health

PDFs

ANF Station Page

MesoWest

61.9331, -164.65553, Elev: 670ft


Permits

LandownerPermit ExpiresNotificationStipulations

Sea Lion Corporation/Hooper Bay Village (K13K)


Close-Out Release

3/1/2021

Yes, for install/removal, NOT service.

Sea Lion Corporation, William Naneng or Myron Naneng, will@sealioncorp.net, (907) 758-4015

None
Looking for labels? They can now be found in the details panel on the floating action bar.