N19K (AEC)

N19K (AEC)

Station Notes

  • Adopted by the AEC
  • A rock wind wall is mounded around the sensor well cap box, but not in contact with the box. No material was available for burying the well cap box.

  • The site is on a plateau below the main peak and the NPS repeater hut at the apex of the hill.

  • The site is high and in a location that likely remains mostly snow free due to wind scouring

Service Plan

Site Access

  • Helicopter

Site Contact

  • None at this time

Site Visits

  •  2019_10_03 Removal (Adopted by AEC)
    STATION CODE: TA.N19K
     
    STATION LOCALE DESCRIPTION: Bonanza Creek NPS repeater, AK, USA
     
    STATION REMOVAL LOG DATE: 20191003
     
    STATION/SENSOR DOWN TIME (UTC): N/A
    
    REMOVAL DESCRIPTION: Site was adopted by AEC and has not been removed.
    
    ACTIONS TAKEN: Site was not visited during the adoption process
    
    LAT/LONG OF SENSOR HOLE: N/A
     
    Top of Casing to hole bottom (indicate if sand present or evacuated): N/A
    Bottom of wellcap to grade level: N/A
    
    SENSOR ORIENTATION MEASUREMENTS: 
    Measured with Octans Unit: N/A
    Measured with rods on pin: N/A
    Casing/wellcap marked with reference orientation: N/A
    
    SENSOR ORIENTATION: N/A
    
    COMMENTS: BGAN site, remote acquisition changeover
    
    REMOVED: N/A
    
    DAMAGE: N/A
    
    LEFT AT SITE: N/A
    
    VISITORS:
    Scott Dalton
    Nate Murphy
    
    NEXT VISIT:  N/A
    
    SITE STATUS:  N/A
    
    HOLE STATUS: N/A
    
  •  2019_06_11 Service (R. Bierma, E. McArthur-AEC)

    USArray Station Service Report
    Form V1.0

    STATION CODE:
    TA.N19K

    STATION Locale Description:
    Bonanza Hill, Alaska

    STATION SERVICE LOG DATE:
    20190611

    STATION/SENSOR DOWN TIME (UTC):

    ~2345-2355 UTC


    SERVICE DESCRIPTION:

    VIE swap

    Vaisala WXT536 installation

    XI-202 install

    LFP test

    Hut vent install


    UPON ARRIVAL:

    The station appeared to be in good shape. No signs of animal damage on hut or wellcap. The conduit was slightly askew with a couple shallow tooth indentions, as if it had been lazily tugged on by an unmotivated bear.

    ACTIONS TAKEN:

    The G4 VIE was swapped for a G5 VIE. Existing Hughes BGAN modem installed in new VIE

    Standard installation of a Vaisala WXT536 weather station and mount. Station includes bird spikes.

    The system LFP batteries were tested using the headlight load kit

    XI-202 was installed and confirmed with firmware and output

    A standard brass hut vent was installed at the peak of the west side.

    The uncovered portion of conduit was piled on with rocks.


    EQUIPMENT REMOVED:

    VIE - 5009223
    NCPA - 5014107 (H302070014)
    Regulator board - 5009851 (213)
    QEP - 5011128 (119583)
    Setra - 5011196 (4620579)
    B44 - 5010839 (18439)
    Genasun CC - 5016770

     

    EQUIPMENT INSTALLED:

    VIE - 5018924
    B44 - 5018876 (17188)
    QEP - 5018895 (5018895) same
    Setra278 - 5018855 (7296197)
    NCPA - 5011754 (H111160378)
    Regulator board - 5018898 (555)
    Genasun CC - no barcode sticker present

    XI-202 - 5018946 (770)

    Vaisala WXT536 - 5019071 (R2220231)



    COMMENTS:

    Hut door was taped prior to departure

    VISITOR:

    Ryan Bierma
    Evan McArthur (AEC)
    Turner Pahl (Alpine Air)


    ON NEXT VISIT:

     A new hut antenna mount will need to be installed in order for the GPS timing antenna to be installed outside.

    CHANGES AFFECT INSTRUMENT RESPONSE:

    None


  • 2016_04_07 Service (D. Bloomquist, J. Theis)
  • 2015_06_12 Install (J. Miner, B. White)

Station Health

PDFs

ANF Station Page

MesoWest

60.81322, -154.48376, Elev: 3753ft


Permits

LandownerPermit ExpiresNotificationStipulations

DNR/State (LAS 29599)


Close-Out Release Form

6/22/2022None
  • None
AEC-Primary Permit HolderNAAECStation adopted on 9/1/2019

Related content