USArray Station Service Report
Form V1.0
STATION CODE:
TA.F18K
STATION Locale Description:
Selawik, Alaska
STATION SERVICE LOG DATE:
20190823
STATION/SENSOR DOWN TIME (UTC):
1845-1945 UTC
SERVICE DESCRIPTION:
Sensor cable repair
Vaisala station swap
Other firmware updates and station checks
UPON ARRIVAL:
The station was in good shape overall. The only noted problemw as that the conduit was diconnected at the wellcap and chewed by a bear.
ACTIONS TAKEN:
A new STS-5A sensor cable was installed in place of the bear chewed cable. The conduit was reattached to the wellcap box. The sensor appeared to be functioning, based on good mass leveling and stomp tests.
A Vaisala WXT536 was installed in place of the failed WXT520. The cable was fine.
The Genasun charge controller was upgraded to firmware 1.20
QEP firmware was updated to 1.10
XI202 firmware was updated to 4286
Baler media was swapped.
No soil data was downloaded.
EQUIPMENT REMOVED:
Vaisala WXT520: sn H1210003, bc 5013029
EQUIPMENT INSTALLED:
Vaisala WXT536: sn R2210116, bc 5019065
COMMENTS:
The sensor was bedded with 1.75L of sand - less than normal since it's an STS5A in PVC (a tighter fit).
OCTANS was used to orient sensor: 0.0 degrees
Door was taped prior to departure
VISITOR:
Jeremy Miner
Ryan Bierma
Turner Pahl (Alpine Air)
ON NEXT VISIT:
There was supposed to be a cell modem upgrade on this trip, but unfortunately due to a mixup we did not bring the RV50 along. The RavenX is still working fine, but the signal was not good (-106 dB).
CHANGES AFFECT INSTRUMENT RESPONSE:
yes